「安全電流」:修訂間差異
跳至導覽
跳至搜尋
| 第7行: | 第7行: | ||
# UL | # UL | ||
== NEC(National Ectrical Code) == | == NEC(National Ectrical Code) == | ||
*[http://goo.gl/EhzgQE Lapp NEC安全電流表] | |||
* Table 310.15(B)(16) | |||
Allowable Ampacities of Insulated Conductors Rated 0 - 2000 Volts, | Allowable Ampacities of Insulated Conductors Rated 0 - 2000 Volts, | ||
60° to 90°C (140° to 194°F) Not More Than Three Conductors | 60° to 90°C (140° to 194°F) Not More Than Three Conductors | ||
in Raceway or Cable or Earth (Directly Buried), | in Raceway or Cable or Earth (Directly Buried), | ||
Based on Ambient Temperature of 30°C (86°F) | Based on Ambient Temperature of 30°C (86°F) | ||
* Table 310.15(B)(17) | |||
Allowable Ampacities of Single Insulated Conductors | Allowable Ampacities of Single Insulated Conductors | ||
Rated 0 - 2000 Volts, In Free Air, | Rated 0 - 2000 Volts, In Free Air, | ||
Based on Ambient Air Temperature of 30°C (86°F) | Based on Ambient Air Temperature of 30°C (86°F) | ||
* Table 310.15(B)(3)(a) | |||
Adjustment Factors for More than Three Current-Carrying Conductors in | Adjustment Factors for More than Three Current-Carrying Conductors in | ||
a Raceway or Cable. | a Raceway or Cable. | ||
Where the number of current-carrying conductors in a raceway or cable | Where the number of current-carrying conductors in a raceway or cable | ||
exceeds three, the allowable ampacities shall be reduced as shown: | exceeds three, the allowable ampacities shall be reduced as shown: | ||
* Table 310.15(B)(2)(a) | |||
Temperature Correction Factors | Temperature Correction Factors | ||
For ambient temperatures other than 30°C (86°F), multiply the allowable | For ambient temperatures other than 30°C (86°F), multiply the allowable | ||
ampacities shown above by the appropriate factor shown below. | ampacities shown above by the appropriate factor shown below. | ||
於 2014年4月23日 (三) 09:56 的修訂
相關安規
- JIS
- CNS
- IEC
- VDE
- DIN VDE 0298-4:2013
- UL
NEC(National Ectrical Code)
- Lapp NEC安全電流表
- Table 310.15(B)(16)
Allowable Ampacities of Insulated Conductors Rated 0 - 2000 Volts, 60° to 90°C (140° to 194°F) Not More Than Three Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F)
- Table 310.15(B)(17)
Allowable Ampacities of Single Insulated Conductors Rated 0 - 2000 Volts, In Free Air, Based on Ambient Air Temperature of 30°C (86°F)
- Table 310.15(B)(3)(a)
Adjustment Factors for More than Three Current-Carrying Conductors in a Raceway or Cable. Where the number of current-carrying conductors in a raceway or cable exceeds three, the allowable ampacities shall be reduced as shown:
- Table 310.15(B)(2)(a)
Temperature Correction Factors For ambient temperatures other than 30°C (86°F), multiply the allowable ampacities shown above by the appropriate factor shown below.