==75℃ Capacitance and Relative test of THHW== | ==75℃ Capacitance and Relative test of THHW== | ||
The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula: | *Capacitance and Relative permittivity | ||
*The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula: | |||
<php> | <php> | ||
εr=13,600*C*log(D/d) | εr=13,600*C*log(D/d) | ||
於 2016年7月4日 (一) 10:13 的修訂
75℃ Capacitance and Relative test of THHW
- Capacitance and Relative permittivity
- The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula:
<php> εr=13,600*C*log(D/d) where r = relative permittivity C = capacitance in microfarads of the immersed 3050 mm (120 in) portion of the specimen D = measured diameter over the insulation, mm (in) d = measured diameter under the insulation, mm (in) </php>
- 90℃ Capacitance and Relative test of THW-2
- 75℃ Capacitance and Relative test of THHW
- 30℃ Capacitance and Relative test of MTW