== | ==75℃ Capacitance and Relative test of THHW== | ||
The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula: | The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula: | ||
<php> | <php> | ||
| 第9行: | 第9行: | ||
d = measured diameter under the insulation, mm (in) | d = measured diameter under the insulation, mm (in) | ||
</php> | </php> | ||
*90℃ Capacitance and Relative test of THW-2 | |||
*75℃ Capacitance and Relative test of THHW | |||
*30℃ Capacitance and Relative test of MTW | |||
於 2016年7月4日 (一) 10:06 的修訂
75℃ Capacitance and Relative test of THHW
The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula: <php> εr=13,600*C*log(D/d) where r = relative permittivity C = capacitance in microfarads of the immersed 3050 mm (120 in) portion of the specimen D = measured diameter over the insulation, mm (in) d = measured diameter under the insulation, mm (in) </php>
- 90℃ Capacitance and Relative test of THW-2
- 75℃ Capacitance and Relative test of THHW
- 30℃ Capacitance and Relative test of MTW