==75℃ Capacitance and Relative test of THHW== *UL 2556 6.5 Capacitance and relative permittivity *The relative permittivity (dielectric constant) of the insulation shall be determined after 1 d by means of the following formula: <php> εr=13,600*C*log(D/d) where r = relative permittivity C = capacitance in microfarads of the immersed 3050 mm (120 in) portion of the specimen D = measured diameter over the insulation, mm (in) d = measured diameter under the insulation, mm (in) </php> *90℃ Capacitance and Relative test of THW-2 *75℃ Capacitance and Relative test of THHW *30℃ Capacitance and Relative test of MTW ==Apparatus== *The apparatus shall consist of the following: ** a capacitance bridge capable of operating at a sinusoidal or nearly sinusoidal voltage at a frequency of 1000 Hz at 10 V or less, or 60 Hz at 3.15 kV/ mm (80 V/mil) of insulation thickness; ** a water tank capable of maintaining the water at the required temperature; and ** a temperature-measuring device with an accuracy of ±1°C.